Current Issue : April-June Volume : 2022 Issue Number : 2 Articles : 5 Articles
Background: To investigate the surgical outcomes of implantable collamer lens (ICL) implantation in eyes with residual myopia after primary laser vision correction (LVC) surgeries. Methods: This study included patients who underwent ICL implantation and had a history of LVC surgery, including photorefractive keratectomy (PRK) or laser-assisted in situ keratomileusis (LASIK). Visual acuity and refractive error were assessed pre and 3-months postoperatively and the efficacy and safety indices calculated accordingly. Results: A total of 30 eyes of 17 patients were included in this study. At 3 months, the mean logMAR uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and spherical equivalent were − 0.03 ± 0.11 (include logMAR), − 0.04 ± 0.09 (include logMAR), and − 0.06 ± 0.33 diopters (D), respectively. The 3-month Snellen UDVA was better than 20/20 for 83% of eyes, and 97% of eyes showed an unchanged or improved CDVA after surgery. The mean efficacy and safety indices were 1.11 ± 0.22 and 1.13 ± 0.20, respectively. Further, 93 and 100% of eyes were within ±0.5 and ± 1.0 D of the attempted spherical equivalent refraction, respectively. Conclusions: ICL implantation in eyes with myopic regression after previous LVC surgery showed safe, effective, and predictable outcomes....
Background: Patient non-compliance, that is, failure to perform standard wear and care orthokeratology (ortho-k) lenses procedures, has been shown to be a major risk factor for contact lens-associated complications. Therefore, this study aimed to investigate the compliance with wear and care behaviors of ortho-k patients and analyze its influencing factors. Methods: Patients who were successfully prescribed ortho-k lenses at the Eye Center of the Second Affiliated Hospital of Zhejiang University School of Medicine (ECSAHZU) were enrolled in the study. Patient compliance with wear and care behaviors was examined through a questionnaire. Results: This study assessed 238 subjects. The subjects’ ages ranged from 7 to 25 (mean ± SD, 11.3 ± 2.5) years. The compliance with wear and care behaviors was 19.7%, and the subjects’ self-assessment compliance was 96.6%. The compliance rate of subjects wearing lenses for less than 1 year was higher than that of subjects wearing lenses for more than 1 year (p < 0.001). In the first year, the compliance rates of wearing experiences for less than 1 month, 1 month, 3 months, 6 months, and more than 6 months were 45, 29, 21.6, 20, and 27.6%, respectively, and there were no statistically significant differences in compliance among these periods (p = 0.314). No correlation was identified between compliance and age (r = − 0.061, p = 0.527) or sex (r = 0.114, p = 0. 751). There was no correlation between compliance and lens care operator (r = − 0.626, p = 0.151). Conclusions: The compliance of ortho-k patients was poor. After wearing ortho-k lenses for more than 1 year, compliance with wear and care behaviors declined. In clinical practice, measures should be taken to solve these problems and improve the safety of wearing ortho-k lenses....
Purpose: To investigate the macular vessel density and thickness in macular-on rhegmatogenous retinal detachment (RRD) after vitrectomy with gas and silicone oil (SO) tamponade. Methods: Patients with macular-on RRD eyes, treated with a single successful vitrectomy with gas or SO tamponade and a minimum 30 months follow-up, were reviewed. Best-corrected visual acuity (BCVA), macular vessel density and retinal thickness by using optical coherence tomography angiography, were compared to the contralateral eyes. Results: Sixteen eyes with gas tamponade and 17 eyes with SO tamponade were included in the study. LogMAR best-corrected visual acuity (BCVA) slightly improved from 0.25 ± 0.18 (Snellen 20/36) to 0.17 ± 0.23 (Snellen 20/30) in eyes with gas tamponade, and decreased from 0.30 ± 0.22 (Snellen 20/40) to 0.49 ± 0.28 (Snellen 20/62) in eyes with SO tamponade. The parafoveal vessel densities in superficial vascular complex (SVC) and the corresponding inner retinal thickness (IRT) were similar between the affected eyes and the contralateral eyes in gas tamponade group (P = 0.578, P = 0.943), while significantly reduced in the affected eyes, compared to the contralateral eyes in SO tamponade group (P < 0.001, P < 0.001). Conclusion: Eyes in SO tamponade group had worse BCVA, lower SVC vessel densities and thinner corresponding IRT after vitrectomy for macular-on RRD, than those in gas tamponade group....
Background: To evaluate quantitative changes in iris blood circulation in patients with ischemic risk. Methods: This observational case-control study included 79 patients with diabetic retinopathy (DR) and retinal vein occlusion (RVO). The RVO group included 21 patients; the monocular proliferative diabetic retinopathy (PDR) group included 19 patients; the nondiabetic retinopathy (NDR) group included 18 patients; and the healthy control group included 21 healthy controls. In the RVO group, we analyzed RVO affected eyes, RVO contralateral eyes, and healthy control eyes. We also compared eyes with PDR and contralateral eyes without PDR, patients with diabetes mellitus (DM) without DR, and healthy control eyes. The microvascular networks of the iris and retina were analyzed using optical coherence tomography angiography. The analysis included vessel area density (VAD) and vessel skeleton density (VSD) of iris and retina. Results: In the RVO group, the VAD and VSD of iris in the affected eye were higher than those in contralateral and healthy control eyes, and the VAD and VSD of contralateral eyes were higher than those of healthy control eyes. The retinal blood flow of the RVO eyes was less than that of the contralateral and healthy control eyes, but there were no difference between the contralateral eyes and healthy control eyes. The VAD and VSD of iris in PDR were larger than nonproliferative diabetic retinopathy (NPDR) and the NPDR were larger than NDR. There were no differences between NDR and healthy control eyes. Also, there were no differences among the four groups with respect to retinal blood flow. Conclusions: Compared with the retina, iris blood circulation quantitative analysis data seem to be more sensitive to ischemia and may be used as a new predictor of ischemic disease, even if further research is needed to better understand the clinical value and importance of this analysis....
Background: Multiple sclerosis (MS) is an autoimmune disease that attacks the central nervous system, with optic neuritis (ON) being a common early manifestation. Retinal nerve fiber layer (RNFL) thickness may be a biomarker of neuroaxonal damage in MS patients. We sought to evaluate changes in RNFL thickness over 4 years in Omani MS patients with or without ON in comparison to a healthy control group. Methods: This retrospective case-control study involved 27 MS patients and 25 healthy controls. Optical coherence tomography was performed upon first diagnosis and at a four-year follow-up. Differences in mean RNFL thickness were calculated. Results: A total of 51 eyes from the MS group and 50 eyes from the control group were evaluated. There was a significant reduction in mean RNFL thickness among MS patients with ON at follow-up (81.21 versus 72.14 μm; P = .003), whereas no significant RNFL thinning was observed among MS patients without ON. However, there was a significant reduction in RNFL thickness among MS patients compared to healthy controls (76.79 versus 93.72 μm; P = .009), regardless of ON presence/absence. Conclusions: Axonal damage was seen in the optic nerves of Omani MS patients. Moreover, there was a significant reduction in RNFL thickness among MS patients with ON as the disease progressed; however, while there was evidence of RNFL thinning in MS patients without ON, this difference lacked statistical significance. Evaluation of RNFL thickness may represent a useful biomarker for monitoring disease progression in MS and its association with ON....
Loading....